{"product_id":"vestwoods-ved-series-liquid-cooled-battery-energy-storage-system","title":"Vestwoods VED Series Liquid-Cooled Battery Energy Storage System","description":"\u003ch2 data-section-id=\"1v6treq\" data-start=\"389\" data-end=\"439\"\u003e1MWh–2MWh Utility-Scale Energy Storage Solution\u003c\/h2\u003e\n\u003cp data-start=\"441\" data-end=\"715\"\u003eThe \u003cstrong data-start=\"445\" data-end=\"520\"\u003eVestwoods VED Series Liquid-Cooled Battery Energy Storage System (BESS)\u003c\/strong\u003e is a next-generation utility-scale energy storage platform designed for renewable energy integration, grid stabilization, industrial applications, and large-scale energy infrastructure projects.\u003c\/p\u003e\n\u003cp data-start=\"717\" data-end=\"965\"\u003eAvailable in capacities from \u003cstrong data-start=\"746\" data-end=\"770\"\u003e1.044MWh to 2.088MWh\u003c\/strong\u003e, the system integrates advanced LiFePO4 battery technology, liquid thermal management, intelligent battery protection, and high-efficiency power conversion into a compact outdoor-ready solution.\u003c\/p\u003e\n\u003cp data-start=\"967\" data-end=\"1137\"\u003eThe VED Series is engineered to maximize system efficiency, extend battery lifespan, and reduce operational costs across utility, commercial, and industrial applications.\u003c\/p\u003e\n\u003chr data-start=\"1139\" data-end=\"1142\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1144\" data-end=\"1158\"\u003eKey Features\u003c\/h1\u003e\n\u003ch2 data-section-id=\"b73ane\" data-start=\"1160\" data-end=\"1198\"\u003eFlexible Capacity from 1MWh to 2MWh\u003c\/h2\u003e\n\u003cp data-start=\"1200\" data-end=\"1250\"\u003eThe VED Series offers two standard configurations:\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1252\" data-end=\"1365\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1252\" data-end=\"1279\"\u003e\n\u003ctr data-start=\"1252\" data-end=\"1279\"\u003e\n\u003cth data-start=\"1252\" data-end=\"1260\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"1260\" data-end=\"1279\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eEnergy Capacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1302\" data-end=\"1365\"\u003e\n\u003ctr data-start=\"1302\" data-end=\"1335\"\u003e\n\u003ctd data-start=\"1302\" data-end=\"1323\" data-col-size=\"sm\"\u003eVED 500K-1044kWh-L\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1323\" data-end=\"1335\"\u003e1.044MWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1336\" data-end=\"1365\"\u003e\n\u003ctd data-start=\"1336\" data-end=\"1353\" data-col-size=\"sm\"\u003eVED 1MW-2MWh-L\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1353\" data-end=\"1365\"\u003e2.088MWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1367\" data-end=\"1470\"\u003eDesigned to support utility-scale renewable energy projects and industrial energy storage applications.\u003c\/p\u003e\n\u003chr data-start=\"1472\" data-end=\"1475\"\u003e\n\u003ch2 data-section-id=\"d2r18e\" data-start=\"1477\" data-end=\"1514\"\u003eAdvanced Liquid Cooling Technology\u003c\/h2\u003e\n\u003cp data-start=\"1516\" data-end=\"1658\"\u003eUnlike traditional air-cooled systems, the VED Series utilizes intelligent liquid cooling technology to maintain optimal battery temperatures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n2y7d0\" data-start=\"1660\" data-end=\"1681\"\u003eBenefits include:\u003c\/h3\u003e\n\u003cul data-start=\"1683\" data-end=\"1879\"\u003e\n\u003cli data-section-id=\"85wg39\" data-start=\"1683\" data-end=\"1713\"\u003eImproved battery consistency\u003c\/li\u003e\n\u003cli data-section-id=\"9ndtmr\" data-start=\"1714\" data-end=\"1740\"\u003eHigher system efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"m2ka4o\" data-start=\"1741\" data-end=\"1768\"\u003eExtended battery lifespan\u003c\/li\u003e\n\u003cli data-section-id=\"1rmigor\" data-start=\"1769\" data-end=\"1816\"\u003eReduced temperature differences between cells\u003c\/li\u003e\n\u003cli data-section-id=\"1y1m0re\" data-start=\"1817\" data-end=\"1849\"\u003eLower maintenance requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1rl5cde\" data-start=\"1850\" data-end=\"1879\"\u003eEnhanced safety performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1881\" data-end=\"1965\"\u003eThe result is greater long-term reliability and lower total cost of ownership (TCO).\u003c\/p\u003e\n\u003chr data-start=\"1967\" data-end=\"1970\"\u003e\n\u003ch2 data-section-id=\"56af2z\" data-start=\"1972\" data-end=\"2015\"\u003eUtility-Grade LiFePO4 Battery Technology\u003c\/h2\u003e\n\u003cp data-start=\"2017\" data-end=\"2084\"\u003eBuilt with high-performance Lithium Iron Phosphate (LFP) batteries:\u003c\/p\u003e\n\u003cul data-start=\"2086\" data-end=\"2170\"\u003e\n\u003cli data-section-id=\"1d2pon5\" data-start=\"2086\" data-end=\"2103\"\u003eSuperior Safety\u003c\/li\u003e\n\u003cli data-section-id=\"1nfci2w\" data-start=\"2104\" data-end=\"2128\"\u003eHigh Thermal Stability\u003c\/li\u003e\n\u003cli data-section-id=\"jvm02h\" data-start=\"2129\" data-end=\"2148\"\u003eLong Service Life\u003c\/li\u003e\n\u003cli data-section-id=\"lwpapo\" data-start=\"2149\" data-end=\"2170\"\u003eHigh Energy Density\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2172\" data-end=\"2196\"\u003eBattery modules feature:\u003c\/p\u003e\n\u003cul data-start=\"2198\" data-end=\"2284\"\u003e\n\u003cli data-section-id=\"6tef8p\" data-start=\"2198\" data-end=\"2223\"\u003e52.2kWh Module Capacity\u003c\/li\u003e\n\u003cli data-section-id=\"1f3r7v5\" data-start=\"2224\" data-end=\"2256\"\u003eIntelligent Battery Management\u003c\/li\u003e\n\u003cli data-section-id=\"imq685\" data-start=\"2257\" data-end=\"2284\"\u003eUtility-Scale Performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2286\" data-end=\"2289\"\u003e\n\u003ch2 data-section-id=\"1xxcn4e\" data-start=\"2291\" data-end=\"2317\"\u003eHigh-Power Grid Support\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1aaalxy\" data-start=\"2319\" data-end=\"2341\"\u003eVED 500K-1044kWh-L\u003c\/h3\u003e\n\u003cul data-start=\"2343\" data-end=\"2384\"\u003e\n\u003cli data-section-id=\"y9s2mw\" data-start=\"2343\" data-end=\"2362\"\u003e500kW Rated Power\u003c\/li\u003e\n\u003cli data-section-id=\"h7wa37\" data-start=\"2363\" data-end=\"2384\"\u003e550kW Maximum Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ksfpw6\" data-start=\"2386\" data-end=\"2404\"\u003eVED 1MW-2MWh-L\u003c\/h3\u003e\n\u003cul data-start=\"2406\" data-end=\"2445\"\u003e\n\u003cli data-section-id=\"1tzyldm\" data-start=\"2406\" data-end=\"2423\"\u003e1MW Rated Power\u003c\/li\u003e\n\u003cli data-section-id=\"pu82rv\" data-start=\"2424\" data-end=\"2445\"\u003e1.1MW Maximum Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2447\" data-end=\"2460\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul data-start=\"2462\" data-end=\"2571\"\u003e\n\u003cli data-section-id=\"1ajv2zf\" data-start=\"2462\" data-end=\"2476\"\u003ePeak Shaving\u003c\/li\u003e\n\u003cli data-section-id=\"1g5qwm0\" data-start=\"2477\" data-end=\"2499\"\u003eFrequency Regulation\u003c\/li\u003e\n\u003cli data-section-id=\"zzcuul\" data-start=\"2500\" data-end=\"2516\"\u003eLoad Balancing\u003c\/li\u003e\n\u003cli data-section-id=\"w66wkp\" data-start=\"2517\" data-end=\"2545\"\u003eRenewable Energy Smoothing\u003c\/li\u003e\n\u003cli data-section-id=\"1edt18x\" data-start=\"2546\" data-end=\"2571\"\u003eGrid Ancillary Services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2573\" data-end=\"2576\"\u003e\n\u003ch2 data-section-id=\"hon6zw\" data-start=\"2578\" data-end=\"2617\"\u003eGrid-Tied and Microgrid Applications\u003c\/h2\u003e\n\u003cp data-start=\"2619\" data-end=\"2684\"\u003eThe VED Series supports a wide range of energy storage scenarios:\u003c\/p\u003e\n\u003ch3 data-section-id=\"1oqz7pr\" data-start=\"2686\" data-end=\"2710\"\u003eUtility Applications\u003c\/h3\u003e\n\u003cul data-start=\"2712\" data-end=\"2800\"\u003e\n\u003cli data-section-id=\"sh57mn\" data-start=\"2712\" data-end=\"2732\"\u003eGrid Stabilization\u003c\/li\u003e\n\u003cli data-section-id=\"1g5qwm0\" data-start=\"2733\" data-end=\"2755\"\u003eFrequency Regulation\u003c\/li\u003e\n\u003cli data-section-id=\"1gj49kn\" data-start=\"2756\" data-end=\"2779\"\u003eRenewable Integration\u003c\/li\u003e\n\u003cli data-section-id=\"cpgjbd\" data-start=\"2780\" data-end=\"2800\"\u003eAncillary Services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"d1bp02\" data-start=\"2802\" data-end=\"2842\"\u003eCommercial \u0026amp; Industrial Applications\u003c\/h3\u003e\n\u003cul data-start=\"2844\" data-end=\"2909\"\u003e\n\u003cli data-section-id=\"mxf1k9\" data-start=\"2844\" data-end=\"2867\"\u003ePeak Demand Reduction\u003c\/li\u003e\n\u003cli data-section-id=\"1k4bed2\" data-start=\"2868\" data-end=\"2894\"\u003eTime-of-Use Optimization\u003c\/li\u003e\n\u003cli data-section-id=\"1sp3vzt\" data-start=\"2895\" data-end=\"2909\"\u003eBackup Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"g10s6l\" data-start=\"2911\" data-end=\"2937\"\u003eMicrogrid Applications\u003c\/h3\u003e\n\u003cul data-start=\"2939\" data-end=\"3014\"\u003e\n\u003cli data-section-id=\"1gaoh6p\" data-start=\"2939\" data-end=\"2959\"\u003eIslanded Operation\u003c\/li\u003e\n\u003cli data-section-id=\"1rvrqpl\" data-start=\"2960\" data-end=\"2980\"\u003eRemote Communities\u003c\/li\u003e\n\u003cli data-section-id=\"18z4y38\" data-start=\"2981\" data-end=\"2999\"\u003eIndustrial Parks\u003c\/li\u003e\n\u003cli data-section-id=\"bb4ska\" data-start=\"3000\" data-end=\"3014\"\u003eMining Sites\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3016\" data-end=\"3019\"\u003e\n\u003ch2 data-section-id=\"rwyfsd\" data-start=\"3021\" data-end=\"3047\"\u003eSmart Energy Management\u003c\/h2\u003e\n\u003cp data-start=\"3049\" data-end=\"3098\"\u003eIntegrated intelligent control platform supports:\u003c\/p\u003e\n\u003cul data-start=\"3100\" data-end=\"3182\"\u003e\n\u003cli data-section-id=\"13c9u7a\" data-start=\"3100\" data-end=\"3122\"\u003eReal-Time Monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"11w2w7s\" data-start=\"3123\" data-end=\"3143\"\u003eRemote Diagnostics\u003c\/li\u003e\n\u003cli data-section-id=\"40ngj1\" data-start=\"3144\" data-end=\"3161\"\u003eEMS Integration\u003c\/li\u003e\n\u003cli data-section-id=\"7esm55\" data-start=\"3162\" data-end=\"3182\"\u003eSCADA Connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3184\" data-end=\"3216\"\u003eCommunication protocols include:\u003c\/p\u003e\n\u003cul data-start=\"3218\" data-end=\"3246\"\u003e\n\u003cli data-section-id=\"179pf00\" data-start=\"3218\" data-end=\"3225\"\u003eRS485\u003c\/li\u003e\n\u003cli data-section-id=\"1m20on4\" data-start=\"3226\" data-end=\"3235\"\u003eCAN Bus\u003c\/li\u003e\n\u003cli data-section-id=\"kwzhuh\" data-start=\"3236\" data-end=\"3246\"\u003eEthernet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3248\" data-end=\"3312\"\u003eEnabling seamless integration into modern energy infrastructure.\u003c\/p\u003e\n\u003chr data-start=\"3314\" data-end=\"3317\"\u003e\n\u003ch2 data-section-id=\"1b6cknh\" data-start=\"3319\" data-end=\"3350\"\u003eIntegrated Safety Protection\u003c\/h2\u003e\n\u003cp data-start=\"3352\" data-end=\"3406\"\u003eThe system incorporates multiple layers of protection:\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r3qip4\" data-start=\"3408\" data-end=\"3430\"\u003eBattery Protection\u003c\/h3\u003e\n\u003cul data-start=\"3432\" data-end=\"3529\"\u003e\n\u003cli data-section-id=\"chcba7\" data-start=\"3432\" data-end=\"3455\"\u003eOvercharge Protection\u003c\/li\u003e\n\u003cli data-section-id=\"9a4qgc\" data-start=\"3456\" data-end=\"3483\"\u003eOver-discharge Protection\u003c\/li\u003e\n\u003cli data-section-id=\"11rszws\" data-start=\"3484\" data-end=\"3508\"\u003eOvercurrent Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1cvkugw\" data-start=\"3509\" data-end=\"3529\"\u003eThermal Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bjks65\" data-start=\"3531\" data-end=\"3550\"\u003eFire Protection\u003c\/h3\u003e\n\u003cul data-start=\"3552\" data-end=\"3646\"\u003e\n\u003cli data-section-id=\"1iizt2d\" data-start=\"3552\" data-end=\"3585\"\u003eAerosol Fire Suppression System\u003c\/li\u003e\n\u003cli data-section-id=\"o6b36g\" data-start=\"3586\" data-end=\"3614\"\u003eIntelligent Fire Detection\u003c\/li\u003e\n\u003cli data-section-id=\"1yq9or9\" data-start=\"3615\" data-end=\"3646\"\u003eMulti-Level Safety Management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1n77mrv\" data-start=\"3648\" data-end=\"3673\"\u003eElectrical Protection\u003c\/h3\u003e\n\u003cul data-start=\"3675\" data-end=\"3737\"\u003e\n\u003cli data-section-id=\"uz6lvb\" data-start=\"3675\" data-end=\"3698\"\u003eIsolation Transformer\u003c\/li\u003e\n\u003cli data-section-id=\"1px0h8t\" data-start=\"3699\" data-end=\"3716\"\u003eFault Detection\u003c\/li\u003e\n\u003cli data-section-id=\"1wjyvgp\" data-start=\"3717\" data-end=\"3737\"\u003eEmergency Shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3739\" data-end=\"3800\"\u003eDesigned to meet stringent utility-scale safety requirements.\u003c\/p\u003e\n\u003chr data-start=\"3802\" data-end=\"3805\"\u003e\n\u003ch2 data-section-id=\"1ew5i1m\" data-start=\"3807\" data-end=\"3838\"\u003eOutdoor Utility-Scale Design\u003c\/h2\u003e\n\u003cp data-start=\"3840\" data-end=\"3874\"\u003eEngineered for harsh environments:\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"4063\"\u003e\n\u003cli data-section-id=\"135aw36\" data-start=\"3876\" data-end=\"3893\"\u003eIP55 Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1qtotxf\" data-start=\"3894\" data-end=\"3922\"\u003eC4 Anti-Corrosion Standard\u003c\/li\u003e\n\u003cli data-section-id=\"12f66uj\" data-start=\"3923\" data-end=\"3957\"\u003eOptional C5 Corrosion Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1mb0eqn\" data-start=\"3958\" data-end=\"4040\"\u003eOperating Temperature:\n\u003cul data-start=\"3985\" data-end=\"4040\"\u003e\n\u003cli data-section-id=\"1jujx29\" data-start=\"3985\" data-end=\"4005\"\u003ePCS: -30°C to 60°C\u003c\/li\u003e\n\u003cli data-section-id=\"152kxi5\" data-start=\"4008\" data-end=\"4040\"\u003eBattery Cabinet: -20°C to 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1encmug\" data-start=\"4041\" data-end=\"4063\"\u003eAltitude up to 3000m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4065\" data-end=\"4107\"\u003eSuitable for long-term outdoor deployment.\u003c\/p\u003e\n\u003chr data-start=\"4109\" data-end=\"4112\"\u003e\n\u003ch1 data-section-id=\"bazihh\" data-start=\"4114\" data-end=\"4136\"\u003eTypical Applications\u003c\/h1\u003e\n\u003ch3 data-section-id=\"ejqu4u\" data-start=\"4138\" data-end=\"4160\"\u003eSolar Power Plants\u003c\/h3\u003e\n\u003cp data-start=\"4162\" data-end=\"4225\"\u003eStore excess solar generation and improve dispatch flexibility.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ntjaeu\" data-start=\"4227\" data-end=\"4251\"\u003eWind Energy Projects\u003c\/h3\u003e\n\u003cp data-start=\"4253\" data-end=\"4301\"\u003eReduce intermittency and improve grid stability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"47egx7\" data-start=\"4303\" data-end=\"4326\"\u003eUtility Substations\u003c\/h3\u003e\n\u003cp data-start=\"4328\" data-end=\"4372\"\u003eProvide grid support and ancillary services.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3f1zne\" data-start=\"4374\" data-end=\"4394\"\u003eIndustrial Parks\u003c\/h3\u003e\n\u003cp data-start=\"4396\" data-end=\"4442\"\u003eReduce energy costs and improve power quality.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vyr6um\" data-start=\"4444\" data-end=\"4460\"\u003eData Centers\u003c\/h3\u003e\n\u003cp data-start=\"4462\" data-end=\"4516\"\u003eDeliver reliable backup power for critical operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1kt4sy5\" data-start=\"4518\" data-end=\"4548\"\u003eEV Charging Infrastructure\u003c\/h3\u003e\n\u003cp data-start=\"4550\" data-end=\"4599\"\u003eSupport fast charging and peak demand management.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xzjaci\" data-start=\"4601\" data-end=\"4623\"\u003eMicrogrid Projects\u003c\/h3\u003e\n\u003cp data-start=\"4625\" data-end=\"4674\"\u003eEnable energy independence and energy resilience.\u003c\/p\u003e\n\u003chr data-start=\"4676\" data-end=\"4679\"\u003e\n\u003ch1 data-section-id=\"6i8ipi\" data-start=\"4681\" data-end=\"4703\"\u003eTechnical Highlights\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4705\" data-end=\"5220\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4705\" data-end=\"4750\"\u003e\n\u003ctr data-start=\"4705\" data-end=\"4750\"\u003e\n\u003cth data-start=\"4705\" data-end=\"4721\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"4721\" data-end=\"4750\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eVED Series Liquid Cooling\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4794\" data-end=\"5220\"\u003e\n\u003ctr data-start=\"4794\" data-end=\"4832\"\u003e\n\u003ctd data-start=\"4794\" data-end=\"4811\" data-col-size=\"sm\"\u003eCapacity Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4811\" data-end=\"4832\"\u003e1.044MWh–2.088MWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4833\" data-end=\"4864\"\u003e\n\u003ctd data-start=\"4833\" data-end=\"4853\" data-col-size=\"sm\"\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4853\" data-end=\"4864\"\u003eLiFePO4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4865\" data-end=\"4894\"\u003e\n\u003ctd data-start=\"4865\" data-end=\"4883\" data-col-size=\"sm\"\u003eModule Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4883\" data-end=\"4894\"\u003e52.2kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4895\" data-end=\"4922\"\u003e\n\u003ctd data-start=\"4895\" data-end=\"4909\" data-col-size=\"sm\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4909\" data-end=\"4922\"\u003e500kW–1MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4923\" data-end=\"4950\"\u003e\n\u003ctd data-start=\"4923\" data-end=\"4935\" data-col-size=\"sm\"\u003eMax Power\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4935\" data-end=\"4950\"\u003e550kW–1.1MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4951\" data-end=\"4994\"\u003e\n\u003ctd data-start=\"4951\" data-end=\"4968\" data-col-size=\"sm\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4968\" data-end=\"4994\"\u003e400V \/ 3W+PE \/ 3W+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4995\" data-end=\"5022\"\u003e\n\u003ctd data-start=\"4995\" data-end=\"5007\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5007\" data-end=\"5022\"\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5023\" data-end=\"5058\"\u003e\n\u003ctd data-start=\"5023\" data-end=\"5040\" data-col-size=\"sm\"\u003eCooling System\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5040\" data-end=\"5058\"\u003eLiquid Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5059\" data-end=\"5087\"\u003e\n\u003ctd data-start=\"5059\" data-end=\"5079\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5079\" data-end=\"5087\"\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5088\" data-end=\"5130\"\u003e\n\u003ctd data-start=\"5088\" data-end=\"5104\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5104\" data-end=\"5130\"\u003eRS485 \/ CAN \/ Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5131\" data-end=\"5167\"\u003e\n\u003ctd data-start=\"5131\" data-end=\"5149\" data-col-size=\"sm\"\u003eFire Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5149\" data-end=\"5167\"\u003eAerosol System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5168\" data-end=\"5220\"\u003e\n\u003ctd data-start=\"5168\" data-end=\"5191\" data-col-size=\"sm\"\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5191\" data-end=\"5220\"\u003eC4 Standard \/ C5 Optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"5222\" data-end=\"5225\"\u003e\n\u003ch1 data-section-id=\"19hip8a\" data-start=\"5227\" data-end=\"5261\"\u003eWhy Choose Vestwoods VED Series?\u003c\/h1\u003e\n\u003cp data-start=\"5263\" data-end=\"5302\"\u003e✓ Utility-Scale Energy Storage Platform\u003c\/p\u003e\n\u003cp data-start=\"5304\" data-end=\"5340\"\u003e✓ Advanced Liquid Cooling Technology\u003c\/p\u003e\n\u003cp data-start=\"5342\" data-end=\"5367\"\u003e✓ Capacity up to 2.088MWh\u003c\/p\u003e\n\u003cp data-start=\"5369\" data-end=\"5393\"\u003e✓ Up to 1MW Output Power\u003c\/p\u003e\n\u003cp data-start=\"5395\" data-end=\"5424\"\u003e✓ Long-Life LiFePO4 Batteries\u003c\/p\u003e\n\u003cp data-start=\"5426\" data-end=\"5455\"\u003e✓ Intelligent EMS Integration\u003c\/p\u003e\n\u003cp data-start=\"5457\" data-end=\"5490\"\u003e✓ Utility-Grade Safety Protection\u003c\/p\u003e\n\u003cp data-start=\"5492\" data-end=\"5522\"\u003e✓ Renewable Energy Integration\u003c\/p\u003e\n\u003cp data-start=\"5524\" data-end=\"5549\"\u003e✓ IP55 Outdoor Deployment\u003c\/p\u003e\n\u003cp data-start=\"5551\" data-end=\"5575\"\u003e✓ Grid \u0026amp; Microgrid Ready\u003c\/p\u003e","brand":"VESTWOODS VN","offers":[{"title":"Default Title","offer_id":44040849195073,"sku":null,"price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0241\/8241\/files\/1_d31a42bf-740e-4ada-8ff3-842042a4e889.jpg?v=1781172349","url":"https:\/\/vn.vestwoods.com\/products\/vestwoods-ved-series-liquid-cooled-battery-energy-storage-system","provider":"VESTWOODS VN","version":"1.0","type":"link"}